Text
Pengambilan Tembaga (II) menggunakan Metode Elektrokoagulasi sistem Al(s) | Cu (II)(aq), KCl(aq) || H2O(l) | C(s)
ABSTRAK
Telah dilakukan penelitian mengenai pengambilan Cu (II) menggunakan metode elektrokoagulasi sistem Al | Cu (II), KCl || H2O | C. Tujuan dari penelitian ini menentukan kondisi optimum dalam proses pengambilan Cu (II) dengan metode elektrokoagulasi menggunakan anoda alumunium dan katoda karbon, membandingkan elektrokoagulasi dan koagulasi terhadap pengambilan Cu (II), mengetahui morfologi permukaan elektroda alumunium sebelum dan sesudah elektrokoagulasi, dan menentukan kinetika elektrokoagulasi pengambilan Cu (II). Beberapa kondisi proses elektrokoagulasi yang divariasikan meliputi pengaruh rapat arus, konsentrasi awal Cu (II), pH larutan, dan waktu proses elektrokoagulasi. Analisis konsentrasi Cu (II) setelah proses elektrokoagulasi menggunakan instrumen Spektrofotometer Serapan Atom (SSA) dan karakterisasi permukaan eletroda alumunium dengan SEM. Hasil penelitian menunjukkan pengambilan Cu (II) dicapai pada rapat arus 38 µA/cm2, konsentrasi awal Cu (II) 45 mg/L, pH larutan 9, dan waktu proses elektrokoagulasi selama 120 menit dengan hasil yang dicapai sebesar 99,9%. Pengambilan Cu (II) lebih efektif dengan metode elektrokoagulasi dibandingkan dengan metode koagulasi. Morfologi permukaan alumunium yang semula tampak halus setelah proses elektrokoagualasi menjadi kasar akibat adanya sebagian alumunium di permukaan elektroda yang larut dalam produksi alumunium hidroksida. Kinetika elektrokoagulasi pengambilan Cu (II) mengikuti reaksi pseudo orde dua, dengan k = 0,16 g.mg-1menit-1.
Kata Kunci : Elektrokoagulasi, Pengambilan Cu (II), Al (OH)3
ABSTRACT
Removal of copper (II) has been done by electrocoagulation method system Al| Cu (II), KCl || H2O | C. hydroxide is an excellent coagulation agent which can be formed through electrolisys process. This study aims to determine the optimum conditions of the electrocoagulation process to removal Cu (II) using aluminum and carbon as anode and cathode, comparing the process electrocoagulation and coagulation to removal Cu (II), knowing the surface morphology of aluminum electrode before and after electrocoagulation, and determine kinetics for removal copper (II) by electrocoagulation method. Some conditions varied include the effect of current density, initial concentration of Cu (II), pH of the solution, and the time of electrocoagulation process. Analysis of Cu (II) concentration after electrocoagulation process using Atomic Absorption Spectrophotometer instrument and surface characterization of aluminum eletrode with SEM. The results showed that Cu (II) removal was achieved at current density of 38 µ A / cm2, initial concentration of Cu (II) 45 mg / L, pH of solution 9, and electrocoagulation time of 120 minutes with 99.9% yield. Removal copper (II) by electrocoagulation is more effective than coagulation. The morphology of the aluminum surface initially appears smooth becomes rough after electrocoagualation process due to the surface of aluminum electrodes dissolved in the production of aluminum hydroxide . The kinetic reaction of Cu (II) follows a pseudo second order reaction, with k = 0,16 g.mg-1menit-1.
Keywords : electrocoagulation, removal of cadmium, Fe (OH)3
1504C18III | 1504 C 18 | Perpustakaan FSM Undip (Referensi) | Tersedia |
Tidak tersedia versi lain