Evaluasi Dosis Paparan Dalam Lapangan Kolimator Menggunakan Filter Aluminium Pada Pesawat Sinar-X Mobile
ABSTRAK
Telah dilakukan pengukuran paparan radiasi dalam lapangan kolimasi menggunakan filter aluminium pada pesawat sinar-X mobile, dengan memvariasikan koordinat X dan Y, jarak dari pusat lapangan kolimasi, dan luas lapangan kolimasi 10 cm x 10 cm dan 12 cm x 12 cm. Tujuan dari penelitian ini adalah menganalisis keakuratan nilai paparan radiasi di setiap titik koordinat lapangan kolimasi pesawat sinar-X mobile Siemens. Untuk mengetahui nilai paparan radiasi dalam lapangan kolimasi pada pesawat sinar-X digunakan multi purpose detector (MPD) merk Piranha dan software Ocean 2014, dan untuk mengetahui keakuratan nilai paparan radiasi di setiap titik koordinat lapangan kolimasi pada pesawat sinar-X menggunakan software Surfer 13. Hasil penelitian grafik paparan radiasi menunjukkan bahwa jarak berpengaruh terhadap intensitas radiasi. Pada hasil penelitian menggunakan filter 4 mm PMMA dan 4 mm Al dengan luas lapangan kolimasi 10 cm x 10 cm pada koordinat X2 dengan jarak titik fokus dari pusat lapangan kolimasi 1,5 cm menghasilkan paparan radiasi sebesar 0,01411 mGy, dan pada luas lapangan kolimasi 12 cm x 12 cm pada koordinat XY4 dengan jarak titik fokus dari pusat lapangan kolimasi 1,5 cm menghasilkan paparan radiasi sebesar 0,01416 mGy. Dalam penelitian ini dapat disimpulkan bahwa terjadi pergeseran paparan radiasi menggunakan filter terpasang 2 mm Al dalam pesawat sinar-X dengan lapangan kolimasi 10 cm x 10 cm bergeser ke koordinat XY4 (-0,35 ; -0,35) sebesar 0,5 cm. Pergeseran paparan radiasi menggunakan filter 4 mm Al + 4 mm PMMA dengan lapangan kolimasi 10 cm x 10 cm bergeser ke koordinat X1 (-0,25 ; 0) sebesar 0,25 cm. Sedangkan pergeseran paparan radiasi dengan lapangan kolimasi 12 cm x 12 cm bergeser ke koordinat X1 (-1 ; 0) sebesar 1 cm. Pergeseran nilai paparan radiasi tersebut berpengaruh secara klinis terhadap pasien.
Kata kunci: Al, pesawat sinar-X mobile, paparan, luas lapangan kolimasi, multi purpose detector,
ABSTRACT
Measurement of radiation exposure in the field of collimation using alumunium filter on mobile x-ray plane has been carried out, by varying the x and x coordinates, the distance from the center of the collimation field, as well as area of 10 cm x 10 cm and 12 cm x 12 cm colimation grounds. The aim of this study is to analyze the accuracy of the radiation exposure value at each point of the collimation coordinate field of x-ray siemens by using an additional 2 mm Al + 4 mm PMMA filter and the field installed in the x-ray plane is 2 mm Al. To know the value of radiation exposure in the field of collimation on x-ray plane, MPD brand piranha and ocean software 2014 were used. And to know the accuracy of the radiation exposure value on the x-ray plane at each point coordinate of collimation field on x-ray plane, surfer 13 software were used. The research result of radiation exposure graph shows that the distance affects the intensity of the radiation. The study uses 4 mm PMMA and 4 mm A1 filters with a collimation field of 10 cm x 10 cm in the X2 coordinate with a focus distance of 1,5 cm from the center of collimation field resulting in radiation exposure of 0,01411 mGy, and with a collimation field of 12 cm x 12 cm in the XY4 coordinate with a focus distance of 1,5 cm from the center of collimation field resulting in radiation exposure of 0,01416 mGy. The conclusion of this study is that there is a radiation exposure shift using 2 mm A1 installed filter in X-ray plane with the collimation field of 10 cm x 10 cm shifting to XY4 coordinate (-0,35 ; -0,35) by 0,5 cm. The radiation exposure shift using 4 mm A1 + 4 mm PMMA filters with the collimation field of 10 cm x 10 cm shifts to X1 coordinate (-0,25 ; 0) by 0,25 cm. While the radiation exposure shift with the collimation field of 12 cm x 12 cm shifts to X1 coordinate (-0,1 ; 0) by 1 cm. Such shift in radiation exposure value is clinically affecting the patient.
Keyword: Al, mobile X-ray, exposure, collimation field width, multi purpose detector
1281D18III | 1281 D 18 | Perpustakaan FSM Undip (Referensi) | Tersedia |
Tidak tersedia versi lain