Text
Rancang Bangun Sistem Monitoring Produksi Gas Hidrogen (H2) Pada Proses Elektrolisis Air Laut Yang Dilengkapi Data Logger
INTISARI
Rancang bangun sistem monitoring produksi gas hidrogen (H2) pada proses elektrolisis air laut yang dilengkapi data logger telah berhasil dibuat. Penelitian ini bertujuan untuk membuat sistem monitoring gas H2 yang diproduksi pada proses elektrolisis air laut. Sistem monitoring ini terdiri dari perangkat keras berupa sel elektrolisis, perangkat sensor, perangkat pemroses, dan perangkat pengirim serta perangkat lunak berupa program monitoring. Konsentrasi gas H2 yang diproduksi dipantau menggunakan sensor gas H2 MQ-8. Sedangkan nilai arus yang dialirkan dideteksi menggunakan sensor arus MAX471. Hasil penelitian menunjukan bahwa sensor gas H2 MQ-8 memiliki error rata-rata kalibrasi sebesar 18,98%, sedangkan sensor arus MAX471 memiliki error rata-rata kalibrasi sebesar 1,86%. Hasil monitoring konsentrasi gas H2 pada tegangan 3 volt, 4,5 volt, dan 6 volt adalah 261 ppm, 1171 ppm, dan 1868 ppm. Hal tersebut membuktikan bahwa tegangan memiliki pengaruh terhadap produksi gas H2. Semua data tersebut telah tersimpan dalam bentuk file dan sesuai dengan data yang ditampilkan saat monitoring.
Kata Kunci: Data logger, elektrolisis, gas hidrogen, konsentrasi, sistem monitoring.
ABSTRACT
The prototyping of hydrogen gas (H2) production monitoring system has been executed on the process of electrolysis of sea water equipped with data logger. The aim of this research is to create a monitoring system of H2 gas that produced on the process of sea water electrolysis. This monitoring system consists of hardware such as electrolysis cell, sensor devices, processing devices, sending devices and software such as monitoring program. The concentration of the produced H2 gas was monitored by using MQ-8 gas sensor. While the current’s value was monitored by using MAX471 current sensor. The results showed that MQ-8 gas sensor has the average error of 18,98%, while MAX471 current sensor has the average error of 1,86%. The results of monitoring of concentration H2 gas are at 3 volt, 4,5 volt, and 6 volt voltage is 261 ppm, 1171 pmm, and 1868 ppm. This results prove that the voltage affects the H2 gas production. All of the datas has been stored into file and appropriate with the data displayed during monitoring process.
Keywords: Concentration, data logger, electrolysis, hydrogen gas, monitoring system.
1209D17IV | Perpustakaan FSM Undip (Referensi) | Tersedia |
Tidak tersedia versi lain