Text
Pengendalian Kualitas Produksi Menggunakan Diagram Kontrol Multivariat T2 Hotelling Dengan GUI Matlab (Studi Kasus: Air PDAM Tirta Moedal Kota Semarang di Instalasi Pengolahan Air Kaligarang IV pada Bulan Maret 2015 – Bulan Februari 2016) 519.535 ARI p
ABSTRAK
Air minum adalah air yang melalui proses pengolahan atau tanpa proses
pengolahan yang memenuhi syarat kesehatan. Standar mutu air minum atau air
untuk kebutuhan rumah tangga ditetapkan berdasarkan Peraturan Menteri
Kesehatan Republik Indonesia tentang syarat-syarat dan pengawasan kualitas air
minum. Proses pengendalian kualitas statistik multivariat yang sering digunakan
adalah diagram kontrol T2 Hotelling. Pada diagram kontrol multivariat T2
Hotelling dengan 14 variabel yaitu kekeruhan, besi (Fe), mangan (Mn), warna,
pH, suhu, klorida, tembaga (Cu), kesadahan, seng (Zn), amonia, aluminium, sulfat
dan jumlah zat padat terlarut (TDS) diperoleh nilai BPA sebesar 39,4107 dan BPB
sebesar 0 terlihat bahwa proses terkendali secara statistik. Setelah diketahui proses
terkendali secara statistik maka dilakukan perhitungan kemampuan proses
menghasilkan nilai kapabilitas lebih dari 1 menunjukkan bahwa proses
pengolahan air sudah berjalan dengan baik. Dalam penggunaannya, GUI Matlab
yang telah dibuat sudah mampu memproses dan mempermudah pengguna untuk
melakukan analisis pada diagram kontrol multivariat T2 Hotelling dan
kemampuan proses.
Kata Kunci: kualitas air, diagram kontrol multivariat T2 Hotelling, kemampuan
proses, GUI.
ABSTRACT
Drinking water is water that has been through a processing or without processing
which fulfill health standards. The quality standards for drinking water or
household water are assigned based on regulation by Health Minister of Indonesia
about drinking water requirements and quality control. Multivariate statistical
quality control process which often used is Hotelling’s T2 control chart. From
Hotelling’s T2 control charts with 14 variables; turbidity, iron (Fe), manganese
(Mn), color, pH, temperature, chloride, copper (Cu), hardness, zinc (Zn),
ammonia, aluminum, sulfate, and Total Dissolved Solids (TDS), obtained 39,4107
of BPA level and 0 of BPB level which shows that the quality is under control
statistically. Since the quality is under control, multivariate process capability
computation is conducted and it produced more than one of capability index
value, which shows the water processing is already went well. GUI Matlab that
had been made is able to process and easier for the users to analyze multivariate
Hotelling’s T2 control charts and process capability.
Keywords: water quality, Hotelling’s T2 control charts, process capability, GUI.